4,018 research outputs found

    Constraints on the Formation of the Globular Cluster IC 4499 from Multi-Wavelength Photometry

    Full text link
    We present new multiband photometry for the Galactic globular cluster IC 4499 extending well past the main sequence turn-off in the U, B, V, R, I, and DDO51 bands. This photometry is used to determine that IC4499 has an age of 12 pm 1 Gyr and a cluster reddening of E(B-V) = 0.22 pm 0.02. Hence, IC 4499 is coeval with the majority of Galactic GCs, in contrast to suggestions of a younger age. The density profile of the cluster is observed to not flatten out to at least r~800 arcsec, implying that either the tidal radius of this cluster is larger than previously estimated, or that IC 4499 is surrounded by a halo. Unlike the situation in some other, more massive, globular clusters, no anomalous color spreads in the UV are detected among the red giant branch stars. The small uncertainties in our photometry should allow the detection of such signatures apparently associated with variations of light elements within the cluster, suggesting that IC 4499 consists of a single stellar population.Comment: accepted to MNRA

    Experimental Procedure for the Metrological Characterization of Time-of-Flight Cameras for Human Body 3D Measurements

    Get PDF
    Time-of-flight cameras are widely adopted in a variety of indoor applications ranging from industrial object measurement to human activity recognition. However, the available products may differ in terms of the quality of the acquired point cloud, and the datasheet provided by the constructors may not be enough to guide researchers in the choice of the perfect device for their application. Hence, this work details the experimental procedure to assess time-of-flight cameras' error sources that should be considered when designing an application involving time-of-flight technology, such as the bias correction and the temperature influence on the point cloud stability. This is the first step towards a standardization of the metrological characterization procedure that could ensure the robustness and comparability of the results among tests and different devices. The procedure was conducted on Kinect Azure, Basler Blaze 101, and Basler ToF 640 cameras. Moreover, we compared the devices in the task of 3D reconstruction following a procedure involving the measure of both an object and a human upper-body-shaped mannequin. The experiment highlighted that, despite the results of the previously conducted metrological characterization, some devices showed evident difficulties in reconstructing the target objects. Thus, we proved that performing a rigorous evaluation procedure similar to the one proposed in this paper is always necessary when choosing the right device

    Monte Carlo-based 3D surface point cloud volume estimation by exploding local cubes faces

    Get PDF
    This article proposes a state-of-the-art algorithm for estimating the 3D volume enclosed in a surface point cloud via a modified extension of the Monte Carlo integration approach. The algorithm consists of a pre-processing of the surface point cloud, a sequential generation of points managed by an affiliation criterion, and the final computation of the volume. The pre-processing phase allows a spatial reorientation of the original point cloud, the evaluation of the homogeneity of its points distribution, and its enclosure inside a rectangular parallelepiped of known volume. The affiliation criterion using the explosion of cube faces is the core of the algorithm, handles the sequential generation of points, and proposes the effective extension of the traditional Monte Carlo method by introducing its applicability to the discrete domains. Finally, the final computation estimates the volume as a function of the total amount of generated points, the portion enclosed within the surface point cloud, and the parallelepiped volume. The developed method proves to be accurate with surface point clouds of both convex and concave solids reporting an average percentage error of less than 7 %. It also shows considerable versatility in handling clouds with sparse, homogeneous, and sometimes even missing points distributions. A performance analysis is presented by testing the algorithm on both surface point clouds obtained from meshes of virtual objects as well as from real objects reconstructed using reverse engineering techniques

    First record of Acanthurus chirurgus (Perciformes: Acanthuridae) in the Mediterranean Sea, with some distributional notes on Mediterranean Acanthuridae

    Get PDF
    The occurrence of the doctorfish Acanthurus chirurgus is reported for the first time in the Mediterranean Sea, off Elba Island, Tyrrhenian Sea (42.726667° N, 10.434444° E). This record is tentatively related to aquarium release. The occurrence of Acanthuridae in the Mediterranean Sea is briefly reviewed, and some distributional notes on Acanthurus coeruleus and Acanthurus monroviae in the Mediterranean are provided

    Prefazione

    Get PDF

    Novel imaging biomarkers: epicardial adipose tissue evaluation

    Get PDF
    Epicardial adipose tissue (EAT) is a metabolically activated beige adipose tissue, non-homogeneously surrounding the myocardium. Physiologically, EAT regulates toxic fatty acids, protects the coronary arteries against mechanical strain, regulates proinflammatory cytokines, stimulates the production of nitric oxide, reduces oxidative stress, and works as a thermogenic source against hypothermia. Conversely, EAT has pathologic paracrine interactions with the surrounded vessels, and might favour the onset of atrial fibrillation. In addition, initial atherosclerotic lesions can promote inflammation and trigger the EAT production of cytokines increasing vascular inflammation, which, in turn, may help the development of collateral vessels but also of self-stimulating, dysregulated inflammatory process, increasing coronary artery disease severity. Variations in EAT were also linked to metabolic syndrome. Echocardiography first estimated EAT measuring its thickness on the free wall of the right ventricle but does not allow accurate volumetric EAT estimates. Cardiac CT (CCT) and cardiac MR (CMR) allow for three-dimensional EAT estimates, the former showing higher spatial resolution and reproducibility but being limited by radiation exposure and long segmentation times, the latter being radiation-free but limited by lower spatial resolution and reproducibility, higher cost, and difficulties for obese patients. EAT radiodensity at CCT could to be related to underlying metabolic processes. The correlation between EAT and response to certain pharmacological therapies has also been investigated, showing promising results. In the future, semi-automatic or fully automatic techniques, machine/deep-learning methods, if validated, will facilitate research for various EAT measures and may find a place in CCT/CMR reporting

    Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates

    Get PDF
    OBJECTIVE. The purpose of this study was to evaluate the quality of dual-source CT images of the coronary arteries in heart transplant recipients with high heart rates. SUBJECTS AND METHODS. Contrast-enhanced dual-source CT coronary angiography was performed on 23 heart transplant recipients (20 men, three women; mean age, 61.1 ± 12.8 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent readers using a 5-point scale (0, not evaluative; 4, excellent quality) assessed the quality of images of coronary segments. RESULTS. The mean heart rate during scanning was 89.2 ± 10.4 beats/min. Interobserver agreement on the quality of images of the whole coronary tree was a kappa value of 0.78 and for selection of the optimal reconstruction interval was a kappa value of 0.82. The optimal reconstruction interval was systole in 17 (74%) of the 23 of heart transplant recipients. At the best reconstruction interval, diagnostic image quality (score ≥ 2) was obtained in 92.1% (303 of 329) of the coronary artery segments. The mean image quality score for the whole coronary tree was 3.1 ± 1.01. No significant correlation between mean heart rate (ρ = 0.31) or heart rate variability (ρ = 0.23) and overall image quality score was observed (p = not significant). CONCLUSION. Dual-source CT acquisition yields coronary angiograms of diagnostic quality in heart transplant recipients. Mean heart rate and heart rate variability during scanning do not have a negative effect on the overall quality of images of the coronary arteries
    corecore